JRS1-D
Relay
1.Fundamental parameter of the main circuit: (a).Rated insulation
voltage 660V. (b).Rated working current 25,36,93A seperately. (c).The
regulatorseal of rated setting current and setting. (d).Current
of the Thermal component(see list 1). 2.Auxiliary Circuit: (a).There
are one pair of N/O and N/C contact with electric insulation ; (b).Rated
insulation Voltage 500V ; (c).Ratd frequency 50-60Hz ; (d).Use
group,rated working voltage,appoint thermal current and ratd
current. Thermal
Relays
JRS1 series thermal relay is suitable for using in the circuits
with rated voltage up to 660V, rated current of 80A (JR2893A),
and rated frequency of AC 50 Hz or 60Hz for over-voltage
protection of AC motor. The relay has the differential mechanism
and temperature compensation and can plug
in CJX2 (LC1-D) series AC contactors. This product is in
accordance with the standard of GB14048.4..
Relay
Socket
We can supply a wide range of relay seats from china.
PC
Board Relay
Contact rating: 1) Contact form: 1A, 1C ; 2) Contact material:
silver alloy ; 3) Max. operation current: 15A ; 4) Min. load:
10mA, DC 5V ; 5) Max. operation voltage: AC 250V / DC 30V ; 6)
Max. operation power: 240VA / 240W ; 7) Rated load: a) 1A: 10A /
AC 240V, 12A / AC 120V, 15A / DC 14V (TUV) ; b) 1C: 10A / AC
120V, 10A / DC 24V, 7A / AC 240V ; 8) Contact resistance:
=<100mΩ. Coil rating: 1) Rated voltage: DC 3 - 48V ; 2)
Nominal operation power: 0.36W / 0.45W / 0.8W ; 3) Insulation
resistance: 100mΩ ; 4) Dielectric strength, between contact,
between coil contact: AC 750V, AC 1,500V ; 5) Ambient
temperature: -40 ~ +70°C ; 6) Operating / release time: 10ms /
5ms ; 7) Mechanical life (min.): 10,000,000hrs ; 8) Electrical
life(min.): 100,000hrs ; 9) External dimensions: 19.0 x 15.5 x
15.0cm ; 10) Weight: 9.5g.
Time
Relay
1) Voltage: AC 24V-220V, 50Hz, DC 24V-100V ; 2) Contact: H3Y-2
ST6P-2, on-delay H3Y-4 ST6P-4 ; 3) Operation: H3Y-2 ST6P-2
time-limit operation/self-resting Feeder
Protection Relay
Current Protection Relay for feeder protection suitable for power
utilities and industrial systems. The current protection relay (ipr-a)
has been designed to measure the line and ground rms currents
under normal conditions or under disturbances. The current
signals are sensed throughout current transformers (ct) from each
line. This information is internally processed by the
microprocessor in order to take the current
Protection actions defined under ANSI, iac or IEC standard.
Applications: Primary and backup protection for utility feeder,
Power plants and industrial distribution systems. Protection of
transformers, overhead lines, cables
And generators. Allows the opening of the switch/disconnector
within
The limits of its capacity, leaving the circuit Interruption
fuses in the case of short circuit.
Reed
Relay
1) Type: Sip (SS) ; 2) Contact arrangements: 1A, 1B ; 3) Contact
current: 1A ; 4) Coil voltage: 1A, 200V DC ; 5) Power
consumption: 0.2 W ; 6) Life: a) Mechanical: 100,000,000 ; b)
Electrical: 10,000,000
LRD
Relay
1) Contact form: 1A, 1B, 1C ; 2) Rated load: a) 12A, 12V AC / 30V
DC ; b) 7A, 250V AC / 30V DC ; 3) Contact resistance: =<100mΩ
; 4) Electrical life: 100,000 hours ; 5) Mechanical life:
10,000,000 hours ; 6) Coil rated voltage: 3-48V DC ; 7) Coil
power: 0.36W, 0.45W ; 8) Coil pick-up voltage: =<75% ; 9) Coil
drop-out voltage: >=10% ; 10) Ambient temperature: -25~+70oC
; 11) Coil and contacts: 1,500V AC/min ; 12) Contact and
contacts: 1,000V AC/min ; 13) Insulation resistance: >=100MΩ
; 14) Mounting form: PCB ; 15) Weight: 10g ; 16) Outer
dimensions: 18.9 x 15.5 x 15mm
Digital
Time Relay Series
The relay adopts integrated circuit, LED digital display and
digital key presetting. It features stable and reliable
operation, high delay precision, wide range of time delay, low
power consumption, artistic appearance, visual and simple delay
adjustment, simple erection and is widely used in automatic
control as delay element.
Solid
State Relay
1) Small volume and dimensions ; 2) Universal fit ; 3) Safety
EGIS cover ; 4) Zero current turn-off ; 5) Input loop and output
loop light isolated ; 6) LED indicator (function and alarm) ; 7)
Internal RC snubber
Magnetic
Latching Relays
Jmx-94f: Outline:38x17.2x30;contact form:1a;contact load:
20a250vac/ 30a250vac/50a250v ; 70a250vac;dissipation:1w;coil
voltage: 5v/9v/12v/ 24v. Jmx-21f: 67x25x47,1a,80a220vac,
dissipation:1.6w, 3v/5v/6v/12v/ 24v.
Jmw-1ma:8.5x8.5x10,2c,0.5a28vdc, dissipation:0.3w, 3v/6v/12v/24v.
Jmw-2m: 9.4x9.4x9.53,2c,1a28vdc, dissipation:0.3w,
3v/6v/12v/26.5v, gjb1042. Jmw-270m: D8.5*7.11,2c,1a28vdc,
dissipation:0.3w, 6v/9v/12v/ 18v/ 27v, gjb1042.
JJR1-S
Thermal Overload Relay
1) Power: three-phase 380V±15% 50Hz ; 2) Motor: three-phase AC
asynchronous motor ; 3) Environmental temperature: -0 ~ 40°C ;
4) Relative humidity: max. 90% (20°C) ; 5) Start frequency:
<15 times/hour
Thermal
Overload Relay
This series of thermal relay can be used in the circuit of 50Hz
or 60Hz, rated insulation voltage 660V, rated current 0.1-93A for
protecting the phase break when the electric motor is overload.
The relay has different mechanism and temperature compensation
and can be plugged in LC1-D series AC contactor. At present, it
is the most advanced thermal relay in the world. Features: 1)
Fundamental parameter of the main circuit ; a) Rated insulation
voltage 660V ; b) Rated working current 25, 36, 93A separately ;
c) The regulator seal of rated setting current ; 2) Auxiliary
circuit: a) There are one pair of N/O and N/C contact with
electric insulation ; b) Rated insulation voltage 500V ; c) Rated
frequency 50-60Hz ; d) Use group, rated working voltage ; 3)
Appoint thermal current and rated current
General
Relays
1) Widely suitable for DC or AC circuit switching in various
automation devices, process control and communication devices,
process control and communication equipment. 2) Stable
performance, high reliability, capable of making and breaking
relatively large load currents, easy to maintain and inspect. 3)
The plug-in base of the relay is suitable for using with standard
8 and 11 pins socket
Miniature
General Purpose Relay
1) Life-span: more than 100 million operations ; 2) DC coils:
115V ; 3) Dry circuit contacts: 2 Amp, 3 Amp, 7.5Amp ; 4) Rugged
construction for high reliability ; 5) Printed circuit or
solder/plug-in terminals ; 6) Sealed type available (2/4 poles)
Signal
Power and Automotive Relays
Features: 1) High switching power, low cost, high performance. 2)
Single and double contact types offer switching capacity of 40A.
3) Automobile alarm/security system relays. Specifications: 1)
Contact arrangement: 1A, 1C, 2A. 2) Contact material: silver
alloy. 3) Contact resistance (6V 1A): 50mΩ (max.). 4)
Nominal switching capacity: 20/30A 14VDC. 5) Max. switching
current: 30A. 6) Max. switching voltage: 75VDC. 6) Max. switching
power: 560W. 7) Expected life (min. ope) mechanical at 120cpm: 1
x 107. 8) Expected life (min. ope) electrical at 20cpm: 1 x 105.
Coil Data: 1) Coil consumption sensitivity: 1.8W or 2.2W. 2) Coil
voltage: 12 - 24VDC. Characteristics: 1) Operation time: 10msec
(max.). 2) Release time: 10msec. (max.). 3) Initial breakdown
voltage between coil and contact: 500V AC (50 / 60Hz) for 1 min
Auto
Relay
BF-200201 Electromechanical Relays w/Contact Load Capacity up to
80A. Contact Form:1C/1A ; Contact Material: AgSn02 ; Rated
Switching Current:40A 14VDC(1A) ; 30A14VDC(1C) ; Max. Switching ;
Voltage:75VDC ; Max switching current:40A ; Rated switching
power:560W (1A) 420W(1C) ; Min. Switching Current & Voltage:
Contact Resistance (Initial) M ohm at 6VDC 1A:50 ; Coil
Voltage:6-24VDC ; Coil Power Consumption (mW):1.6W.
High
Voltage Vacuum Relay
We can supply High Voltage Vacuum Relay from china.
Counter
Relay THJ-A
1) Outline dimension: 70 x 90 x 132mm ; 2) Counting range:
1-999999 ; 3) Counting mode: up/down count, random up/down count
; 4) Input signal: contact input or pulse voltage input ; 5)
Counting velocity: low speed: 30cps, high speed: 2000cps ; 6)
Contact: preset control contact: 1C, advancing amount of control
contact: 1C ; 7) Contact capacity: AC2205V (Resistance) ; 8)
Power cut maintained: 5 years ; 9) Operating: AC24V, 36V, 110V,
127V, 220V, 380V50HZ,DC24V ; 10) Fixing mode: flush mounting
Power
Relay
1) Suitable for AC and DC circuit switching and process ; 2)
Control of various automatic devices, communication equipment,
etc.
Thermal
Relay 3UA
1) Suitable for using in power system with AC 50Hz, rate
operation voltage up to 660V and 1,000V, in main circuit, current
from 0.1A to 630A. It is used to protect AC three-phase
asynchronous motor against overload and open-phase. 2) The
current setting value can be regulated and the setting current
values of many thermal elements are intercrossing overlapping
arrangement, for easy selecting by customers from -25°C to 55°C
air temperature as the products have temperature compensating. 3)
The relays have the test push-button for breaking NC contacts,
the operating indications and free trip characteristics. 4)
Conforms to the IEC60947-4 standard
SMB
Automotive Relay
1) Contact form: 2a, 2b, 2c ; 2) Rated load: 5A - 250V AC / 28V
DC ; 3) Contact resistance: ≤50m (Ohm) ; 4) Electrical
life: 100,000hours ; 5) Mechanical life: 10,000,000hours ; 6)
Coil rated voltage: 3 - 110V DC, 5 - 220V AC ; 7) Coil power:
0.9W, 1.2W, 1.2V AC ; 8) Coil pick-up voltage: ≤75%,
≤80% ; 9) Coil drop-out voltage: ≥15%, ≥30% ;
10) Ambient temperature: -25 - 70°C ; 11) Coil and contacts:
1,500V AC/min ; 12) Contact and contacts: 1,000V AC/min ; 13)
Insulation resistance: ≥100m (Ohm) ; 14) Mounting form: PCB
plug-in ; 15) Weight: 35g ; 16) Outer dimensions: 27.5 x 21.5 x
35.2mm
AC
Voltage Relay
1) SVR power monitor is a new type high-tech patented product
employing digital integrated circuit of large scale ; 2) It is
mainly applied in the circuit with AC being 50/60Hz and rated
voltage being below 250V, and is to provide relay protection for
single-phase electromotor of over-high voltage and over-low
voltage ; 3) It is surely a good partner with which electromotor
can work in great safety
Three
Phase Solid State Relay
The TAECL three phase solid state relay is the direct replacement
of electromechnical contractors with all the advantages of
electronic control. The new generation technology, FUSED COPPER
PROCESS is adopted for better thermal performance translating
into cooler running devices with the added life and reliability
for internal components. All SSRs are equipped with 4 KV
optocouplers. Triacs are used for 16 A, 25 A and 40 A with
reverse blocking voltage 1000 V. While for higher current in the
range of 16 A to 300 A BACK TO BACK SCRs are used. The thyristor
output SSRs are available with 1600 V reverse blocking voltage.
Relay
And Series Products
Our company mainly produces series products, such as, small type
electromagnetic relay. Super time relay, water level control,
wiring board, electric protector, carbon brush and button swish,
etc.
|